Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters

Language
Document Type
Year range
1.
ERJ Open Res ; 8(4)2022 Oct.
Article in English | MEDLINE | ID: covidwho-2089155

ABSTRACT

Introduction: Continuous positive airway pressure (CPAP) titration was dramatically affected by the coronavirus disease 2019 (COVID-19) pandemic due to increased biological risk. This study aimed to compare successful CPAP adaptation and compliance with home telemedicine CPAP titration with the usual method based on face-to-face visits. Methodology: A prospective cohort using telemedicine home CPAP titration and follow-up during the COVID-19 pandemic (TC) was compared with a retrospective cohort receiving face-to-face pre-pandemic home titration (RC). The TC included a subgroup with a smartphone application (TC-APP). Successful CPAP adaptation and compliance at 1 month of follow-up were the main endpoints, while patient satisfaction and costs were secondary endpoints. Results: 210 consecutive patients were evaluated (80 RC and 130 TC). 36 patients were in the TC-APP subgroup. CPAP titration was successful in 90% in RC versus 95% in TC and 100% in TC-APP. No compliance differences between groups were found at 1  month (4.79 h·night-1 RC, 4.33  h·night-1 TC and 4.59 h·night-1 TC-APP). Mean±sd patient satisfaction out of 10 was 7.69±2.05 in RC versus 9.02±0.64 in TC (p<0.001). 64% of the TC-APP subgroup reported that their telemedicine strategy influenced an increase in CPAP use (p=0.011). CPAP adaptation with follow-up had an estimated direct staff cost per patient of EUR 19.61±8.61 in TC with no smartphone application used versus EUR 23.79±9.94 in TC-APP (p=0.048). Conclusions: Telemedicine in CPAP titration and early follow-up is equivalent to the usual care in terms of successful adaptation and compliance, while achieving greater patient satisfaction.

2.
Emerg Infect Dis ; 28(11): 2181-2189, 2022 Nov.
Article in English | MEDLINE | ID: covidwho-2054900

ABSTRACT

We compared hospital-acquired catheter-related bacteremia (CRB) episodes diagnosed at acute care hospitals in Catalonia, Spain, during the COVID-19 pandemic in 2020 with those detected during 2007-2019. We compared the annual observed and predicted CRB rates by using the negative binomial regression model and calculated stratified annual root mean squared errors. A total of 10,030 episodes were diagnosed during 2007-2020. During 2020, the observed CRB incidence rate was 0.29/103 patient-days, whereas the predicted CRB rate was 0.14/103 patient-days. The root mean squared error was 0.153. Thus, a substantial increase in hospital-acquired CRB cases was observed during the COVID-19 pandemic in 2020 compared with the rate predicted from 2007-2019. The incidence rate was expected to increase by 1.07 (95% CI 1-1.15) for every 1,000 COVID-19-related hospital admissions. We recommend maintaining all CRB prevention efforts regardless of the coexistence of other challenges, such as the COVID-19 pandemic.


Subject(s)
Bacteremia , COVID-19 , Humans , Spain/epidemiology , Incidence , COVID-19/epidemiology , Pandemics , Bacteremia/etiology , Catheters/adverse effects
3.
ERJ open research ; 2022.
Article in English | EuropePMC | ID: covidwho-1918556

ABSTRACT

Obstructive sleep apnea (OSA) is a highly prevalent chronic disease associated with important comorbidities such as traffic accidents, cardiovascular and metabolic diseases and mortality, among others [1]. Continuous positive airway pressure (CPAP), a first-line therapy in moderate-severe OSA [2], has been proven successful in improving daytime sleepiness, quality of life, reducing traffic accidents [3], improving hypertension and paroxistical atrial fibrillation [4, 5]. However, 47% of successfully titrated patients abandon treatment within three years [5, 6]. Thus, early OSA and CPAP education with close follow-up is mandatory to achieve satisfactory CPAP compliance [6, 7]. In that context, telemedicine and telemonitoring through remote monitoring CPAP have become promising strategies [8, 9]. Recently, smartphone applications [10] and wearables [11] have been added as new suggested tools for improving CPAP compliance.

SELECTION OF CITATIONS
SEARCH DETAIL